Skip to content
automatic gearbox control unit repair TEMIC 01J927156HH

TEMIC 01J927156HH

This control unit comes from a MULTITRONIC VL300 gearbox

Call us

Fault description

The gearbox was running in limp mode. The whole PRND display was lit up, all positions at once. The diagnostic computer was showing fault codes. Additional identification data: 405, vl300, 00107426A3, 00528790, 919183, 107256, PBT-GF 30 Control unit production date: 19.03.2004.

Fault codes

Transmission output speed sensor 2 (G196). No signal.

Transmission range sensor (P/N/D etc.) (F125). Implausible signal.